EM84 Siemens OS

Siemens-labelled EM84 OS tuning-indicator valve with a linear display. Historical Philips data gives a 6.3 V, 210 mA heater and nine-pin Noval base. Ask about the available item’s display condition before ordering.

Enquiry-only item. Contact Glass Audio for a price and to confirm the details you need before purchase. Please include the item name and quantity.

Enquire about this item

Pretoria collection is by prior arrangement. International postage is quoted for the destination.

Description

EM84 Siemens OS tuning indicator

The EM84 combines a visual indicator system with a triode amplifier for tuning indication or modulation control in a suitable circuit. It is not a conventional audio output valve, and its role is to display a circuit-derived indication rather than produce a particular audio tone.

Historical EM84 reference

  • Function: tuning indicator with triode amplifier.
  • Heater: 6.3 V AC or DC, 210 mA in the cited Philips data.
  • Base: nine-pin Noval.
  • Display: a linear luminescent indication whose response depends on the surrounding circuit and operating conditions.

The Philips sheet gives a 250 V operating example with specified electrode connections and external resistors. This is not a heater voltage or a universal supply recommendation. Read the complete diagram and limits for the actual equipment.

Ask about condition and the required replacement

The catalogue’s OS designation means old stock; it does not establish unused NOS condition. A Siemens label and historical type sheet do not certify the manufacturing date, remaining life, display brightness or response of this individual valve. Glass Audio tests valves before sale; please ask what condition information and display observations are available for your purchase.

Do not assume that EM81, EM84, EM86 or another nine-pin indicator can be interchanged without checking its exact connections, control response, heater load and physical viewing arrangement.

Valve-radio and amplifier circuits can retain dangerous voltages after disconnection. Internal servicing and compatibility checks should be handled by a suitably qualified technician.

Reference and enquiries

Historical Philips EM84 data, January 1970. This is a model reference, not a Siemens specimen test certificate.

Visit the datasheet library or enquire about this EM84 with your equipment model and required valve designation. International postage is calculated before a quote; Pretoria collection is by prior arrangement.

Reviews

There are no reviews yet.

Be the first to review “EM84 Siemens OS”